KMDA 7473 FL-U Silence - Induction hob with integrated vapour extraction 
   

KMDA 7473 FL-U Silence
Induction hob with integrated vapour extraction  with Silence motor and 2 Flex zones for recirculation mode  

Price: INR 399,990.00 
KMDA7473 FL-U Silence

More product information

Induction hob with integrated vapour extraction  with Silence motor and 2 Flex zones for recirculation mode  


  • The quietest TwoInOne from Miele – Silence motor  

    Silence motor 

    Extra-quiet: developed by Miele, this motor is 25 % quieter than its predecessor at higher air throughput levels.
  • Flexible installation – ducted recirculation (e.g. with DFKS-UR) or Plug & Play
  • Ample space – 4 large cooking zones incl. 2 Flex zones  

    FlexZone 

    Unique space provision: the Miele FlexZones allow you to position large pots and pans behind each other. 
  • Automatic fan power regulation – Con@ctivity

    Con@ctivity

    Innovative convenience: the cooker hood reacts automatically to settings on the hob.
  • Compact control using the numerical display – ComfortSelect Plus 

    ComfortSelect Plus 

    Compact and convenient: all cooking zones and the fan can be operated using a clear central numerical display.

Downloads - KMDA 7473 FL-U Silence

User manual & Assembly

Description Format Download
Guarantee bookletpdf Download
Operating instructions accessoriespdf Download
Product Sheetpdf Download

CAD data / BIM data

Description Format Download
3D data FBXzip Download
3D data DWGzip Download
3D data RFAzip Download
3D data IFCzip Download
3D data RVTzip Download

Installation drawings

Installation drawings

Whether you want to replace a household appliance or planning a kitchen - here you will find all the relevant installation diagrams for your Miele appliance.

If you want to download an installation diagram, please click on the appropriate image and the high-resolution version is displayed. To download, click the right mouse button and save the image on your computer.

Please note that the installation and maintenance of our equipment should only be performed by a licensed contractor. For questions, please call us and we will advise you without any obligation!

explanations

KMDA7272FL, KMDA7473FL - Side view flush+X, Plug&Play - Installation drawing

①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is 555 mm from the worktop front, the Plug&Play adapter must be extended with a supplementary set from Miele., ②The removable drip tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., , x Dimension by which the worktop depth is greater than 600 mm.

explanations

KMDA7272FL, KMDA7473FL - Side view lying on top+X, Plug&Play - Installation drawing

①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is 555 mm from the worktop front, the Plug&Play adapter must be extended with a supplementary set from Miele., ②The removable drip tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., , x Dimension by which the worktop depth is greater than 600 mm.

explanations

KMDA7272FL/FR, KMDA7473FL/FR, Air circulation (Installation drawing)

explanations

KMDA7272FL/FR, KMDA7473FL/FR, Plug&Play (Installation drawing)

explanations

KMDA7272FL, KMDA7473FL - Side view lying on top, Plug&Play - Installation drawing

①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm².

explanations

KMDA7272FL, KMDA7473FL - flush installation, drilling template, Installation depth 20 cm, Installation drawing

explanations

KMDA7272FL/FR, KMDA7473FL/FR - surface installation, 21 cm, drilling template, Installation drawing

explanations

KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 6 Circulating air - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-V, 5) DUU 1500, , The minimum depth of the cabinet is 935 mm.

explanations

KMDA7272FL/FR, KMDA7473FL/FR - surface installation, drilling template, Installation drawing

explanations

KMDA7272FL, KMDA7473FL - flush installation, drilling template, Installation depth 21 cm, Installation drawing

explanations

KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 5 Circulating air - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm.

explanations

KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 4 Circulating air - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm.

explanations

KMDA7272FL/FR, KMDA7473FL/FR -Installation variant 3 Basis - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90

explanations

KMDA7272FL, KMDA7473FL - Installation drawing

1) Front, 2) Removable drip tray, 3) Cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&Play operation: ≥10 mm - ≤40 mm

explanations

KMDA7272FL, KMDA7473FL - flush - Installation drawing

1) Front, 2) removable drip tray, 3) cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Step milling natural stone worktop, 6) Wooden strip 12 mm (not included in delivery), 7) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&play operation: ≥10 mm - ≤40 mm

explanations

KMDA7272FL, KMDA7473FL - Side view flush, Plug&Play - Installation drawing

①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the ventilation opening must be at least 425 cm².

explanations

KMDA7473FL/FR - Operating options

✓✓ Possible, ✓ Possible - further accessories necessary, - Programming must be changed - further accessories necessary

explanations

KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 13 Circulating air - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1125 mm.

explanations

KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 2 Basis - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90

explanations

KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 1 Basis -drawing

1) DFK-AK 90, 2) DFK-R 1000

explanations

KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 14 Circulating air - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 900 mm.

Image(s) as examples, to illustrate